Telco’s skirting heater type TRLU is a low-temperature convection heater. It’s only 79 mm high. TRLU is a particularly solid heater designed for external controls. It is an ideal heat source for Construction hut’s, greenhouses, wardrobes, drying cabinets and other wet or dry rooms.

Data sheet and assembly instructions

TypeEL numberPowerHeightLengthDepthDescription
TRLU 0854 493 10800 W79 mm2303 mm83 mmLow-temperature skirting heater with thermal cut-out. For fixed installation and external control
Floor brackets54 490 20

The heater is manufactured from extruded aluminium sections. The complete heating element is also made from aluminium and incorporates a heating coil, insulation, cooling fins and connection lead in one unit. This is a tried and tested design that provides excellent heat distribution and a long lifetime.

The heater must be fitted horizontally and is supplied with solid aluminium mountings.
Installation on the floor close to the wall is possible using special floor brackets.
Standard connection: Right hand side.

TRLU can be painted in special colours (link to page) and supplied with curtain clamps and floor brackets.

Specifications
Flow-through heater for external control and permanent installation.
230 V
Colour: Pearl white
Splashproof and rustproof; can be used in wet rooms.
Connection: Right-hand side
Wall mounting: Heaters must be fitted horizontally and are delivered with sturdy wall brackets.
Floor installation: Heaters can be mounted to the floor using floor brackets that need to be ordered separately
Max. surface temperature: 57°C
Installation distance requirementsTRLU
Minimum distance to side wall:2 cm
Minimum distance to floor:5 cm
Minimum distance to ceiling or window sill:15 cm